Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 54
Filter
1.
Intensive Care Med Exp ; 12(1): 31, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38512544

ABSTRACT

BACKGROUND: The individual components of mechanical ventilation may have distinct effects on kidney perfusion and on the risk of developing acute kidney injury; we aimed to explore ventilatory predictors of acute kidney failure and the hemodynamic changes consequent to experimental high-power mechanical ventilation. METHODS: Secondary analysis of two animal studies focused on the outcomes of different mechanical power settings, including 78 pigs mechanically ventilated with high mechanical power for 48 h. The animals were categorized in four groups in accordance with the RIFLE criteria for acute kidney injury (AKI), using the end-experimental creatinine: (1) NO AKI: no increase in creatinine; (2) RIFLE 1-Risk: increase of creatinine of > 50%; (3) RIFLE 2-Injury: two-fold increase of creatinine; (4) RIFLE 3-Failure: three-fold increase of creatinine; RESULTS: The main ventilatory parameter associated with AKI was the positive end-expiratory pressure (PEEP) component of mechanical power. At 30 min from the initiation of high mechanical power ventilation, the heart rate and the pulmonary artery pressure progressively increased from group NO AKI to group RIFLE 3. At 48 h, the hemodynamic variables associated with AKI were the heart rate, cardiac output, mean perfusion pressure (the difference between mean arterial and central venous pressures) and central venous pressure. Linear regression and receiving operator characteristic analyses showed that PEEP-induced changes in mean perfusion pressure (mainly due to an increase in CVP) had the strongest association with AKI. CONCLUSIONS: In an experimental setting of ventilation with high mechanical power, higher PEEP had the strongest association with AKI. The most likely physiological determinant of AKI was an increase of pleural pressure and CVP with reduced mean perfusion pressure. These changes resulted from PEEP per se and from increase in fluid administration to compensate for hemodynamic impairment consequent to high PEEP.

2.
Am J Respir Crit Care Med ; 207(9): 1183-1193, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36848321

ABSTRACT

Rationale: In the EOLIA (ECMO to Rescue Lung Injury in Severe ARDS) trial, oxygenation was similar between intervention and conventional groups, whereas [Formula: see text]e was reduced in the intervention group. Comparable reductions in ventilation intensity are theoretically possible with low-flow extracorporeal CO2 removal (ECCO2R), provided oxygenation remains acceptable. Objectives: To compare the effects of ECCO2R and extracorporeal membrane oxygenation (ECMO) on gas exchange, respiratory mechanics, and hemodynamics in animal models of pulmonary (intratracheal hydrochloric acid) and extrapulmonary (intravenous oleic acid) lung injury. Methods: Twenty-four pigs with moderate to severe hypoxemia (PaO2:FiO2 ⩽ 150 mm Hg) were randomized to ECMO (blood flow 50-60 ml/kg/min), ECCO2R (0.4 L/min), or mechanical ventilation alone. Measurements and Main Results: [Formula: see text]o2, [Formula: see text]co2, gas exchange, hemodynamics, and respiratory mechanics were measured and are presented as 24-hour averages. Oleic acid versus hydrochloric acid showed higher extravascular lung water (1,424 ± 419 vs. 574 ± 195 ml; P < 0.001), worse oxygenation (PaO2:FiO2 = 125 ± 14 vs. 151 ± 11 mm Hg; P < 0.001), but better respiratory mechanics (plateau pressure 27 ± 4 vs. 30 ± 3 cm H2O; P = 0.017). Both models led to acute severe pulmonary hypertension. In both models, ECMO (3.7 ± 0.5 L/min), compared with ECCO2R (0.4 L/min), increased mixed venous oxygen saturation and oxygenation, and improved hemodynamics (cardiac output = 6.0 ± 1.4 vs. 5.2 ± 1.4 L/min; P = 0.003). [Formula: see text]o2 and [Formula: see text]co2, irrespective of lung injury model, were lower during ECMO, resulting in lower PaCO2 and [Formula: see text]e but worse respiratory elastance compared with ECCO2R (64 ± 27 vs. 40 ± 8 cm H2O/L; P < 0.001). Conclusions: ECMO was associated with better oxygenation, lower [Formula: see text]o2, and better hemodynamics. ECCO2R may offer a potential alternative to ECMO, but there are concerns regarding its effects on hemodynamics and pulmonary hypertension.


Subject(s)
Acute Lung Injury , Hypertension, Pulmonary , Animals , Carbon Dioxide , Hydrochloric Acid , Oleic Acid , Respiration, Artificial/methods , Swine
3.
Br J Anaesth ; 130(3): 360-367, 2023 03.
Article in English | MEDLINE | ID: mdl-36470747

ABSTRACT

BACKGROUND: Ventilatory ratio (VR) has been proposed as an alternative approach to estimate physiological dead space. However, the absolute value of VR, at constant dead space, might be affected by venous admixture and CO2 volume expired per minute (VCO2). METHODS: This was a retrospective, observational study of mechanically ventilated patients with acute respiratory distress syndrome (ARDS) in the UK and Italy. Venous admixture was either directly measured or estimated using the surrogate measure PaO2/FiO2 ratio. VCO2 was estimated through the resting energy expenditure derived from the Harris-Benedict formula. RESULTS: A total of 641 mechanically ventilated patients with mild (n=65), moderate (n=363), or severe (n=213) ARDS were studied. Venous admixture was measured (n=153 patients) or estimated using the PaO2/FiO2 ratio (n=448). The VR increased exponentially as a function of the dead space, and the absolute values of this relationship were a function of VCO2. At a physiological dead space of 0.6, VR was 1.1, 1.4, and 1.7 in patients with VCO2 equal to 200, 250, and 300, respectively. VR was independently associated with mortality (odds ratio [OR]=2.5; 95% confidence interval [CI], 1.8-3.5), but was not associated when adjusted for VD/VTphys, VCO2, PaO2/FiO2 (ORadj=1.2; 95% CI, 0.7-2.1). These three variables remained independent predictors of ICU mortality (VD/VTphys [ORadj=17.9; 95% CI, 1.8-185; P<0.05]; VCO2 [ORadj=0.99; 95% CI, 0.99-1.00; P<0.001]; and PaO2/FiO2 (ORadj=0.99; 95% CI, 0.99-1.00; P<0.001]). CONCLUSIONS: VR is a useful aggregate variable associated with outcome, but variables not associated with ventilation (VCO2 and venous admixture) strongly contribute to the high values of VR seen in patients with severe illness.


Subject(s)
Respiratory Distress Syndrome , Humans , Retrospective Studies , Respiratory Distress Syndrome/therapy , Respiration , Italy , Respiratory Dead Space , Respiration, Artificial
4.
J Appl Physiol (1985) ; 133(5): 1212-1219, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36173324

ABSTRACT

The amount of energy delivered to the respiratory system is recognized as a cause of ventilator-induced lung injury (VILI). How energy dissipation within the lung parenchyma causes damage is still a matter of debate. Expiratory flow control has been proposed as a strategy to reduce the energy dissipated into the respiratory system during expiration and, possibly, VILI. We studied 22 healthy pigs (29 ± 2 kg), which were randomized into a control (n = 11) and a valve group (n = 11), where the expiratory flow was controlled through a variable resistor. Both groups were ventilated with the same tidal volume, positive end-expiratory pressure (PEEP), and inspiratory flow. Electric impedance tomography was continuously acquired. At completion, lung weight, wet-to-dry ratios, and histology were evaluated. The total mechanical power was similar in the control and valve groups (8.54 ± 0.83 J·min-1 and 8.42 ± 0.54 J·min-1, respectively, P = 0.552). The total energy dissipated within the whole system (circuit + respiratory system) was remarkably different (4.34 ± 0.66 vs. 2.62 ± 0.31 J/min, P < 0.001). However, most of this energy was dissipated across the endotracheal tube (2.87 ± 0.3 vs. 1.88 ± 0.2 J/min, P < 0.001). The amount dissipated into the respiratory system averaged 1.45 ± 0.5 in controls versus 0.73 ± 0.16 J·min-1 in the valve group, P < 0.001. Although respiratory mechanics, gas exchange, hemodynamics, wet-to-dry ratios, and histology were similar in the two groups, the decrease of end-expiratory lung impedance was significantly greater in the control group (P = 0.02). We conclude that with our experimental conditions, the reduction of energy dissipated in the respiratory system did not lead to appreciable differences in VILI.NEW & NOTEWORTHY Energy dissipation within the respiratory system is a factor promoting ventilator-induced lung injury (VILI). In this animal study, we modulated the expiratory flow, reducing the energy dissipated in the system. However, this reduction happened mostly across the endotracheal tube, and only partly in the respiratory system. Therefore, in healthy lungs, the advantage in energy dissipation does not reduce VILI, but the advantages might be more relevant in diseased lungs under injurious ventilation.


Subject(s)
Lung Injury , Ventilator-Induced Lung Injury , Animals , Swine , Ventilator-Induced Lung Injury/etiology , Tidal Volume , Positive-Pressure Respiration/methods , Respiratory Mechanics , Exhalation , Respiration, Artificial/adverse effects , Respiration, Artificial/methods , Lung
5.
Physiol Rep ; 10(6): e15225, 2022 03.
Article in English | MEDLINE | ID: mdl-35340133

ABSTRACT

The extent of ventilator-induced lung injury may be related to the intensity of mechanical ventilation--expressed as mechanical power. In the present study, we investigated whether there is a safe threshold, below which lung damage is absent. Three groups of six healthy pigs (29.5 ± 2.5 kg) were ventilated prone for 48 h at mechanical power of 3, 7, or 12 J/min. Strain never exceeded 1.0. PEEP was set at 4 cmH2 O. Lung volumes were measured every 12 h; respiratory, hemodynamics, and gas exchange variables every 6. End-experiment histological findings were compared with a control group of eight pigs which did not undergo mechanical ventilation. Functional residual capacity decreased by 10.4% ± 10.6% and 8.1% ± 12.1% in the 7 J and 12 J groups (p = 0.017, p < 0.001) but not in the 3 J group (+1.7% ± 17.7%, p = 0.941). In 3 J group, lung elastance, PaO2 and PaCO2 were worse compared to 7 J and 12 J groups (all p < 0.001), due to lower ventilation-perfusion ratio (0.54 ± 0.13, 1.00 ± 0.25, 1.78 ± 0.36 respectively, p < 0.001). The lung weight was lower (p < 0.001) in the controls (6.56 ± 0.90 g/kg) compared to 3, 7, and 12 J groups (12.9 ± 3.0, 16.5 ± 2.9, and 15.0 ± 4.1 g/kg, respectively). The wet-to-dry ratio was 5.38 ± 0.26 in controls, 5.73 ± 0.52 in 3 J, 5.99 ± 0.38 in 7 J, and 6.13 ± 0.59 in 12 J group (p = 0.03). Vascular congestion was more extensive in the 7 J and 12 J compared to 3 J and control groups. Mechanical ventilation (with anesthesia/paralysis) increase lung weight, and worsen lung histology, regardless of the mechanical power. Ventilating at 3 J/min led to better anatomical variables than at 7 and 12 J/min but worsened the physiological values.


Subject(s)
Respiration, Artificial , Ventilator-Induced Lung Injury , Animals , Lung/pathology , Respiration, Artificial/adverse effects , Respiratory Function Tests , Respiratory Rate , Swine
6.
Crit Care Med ; 50(7): e630-e637, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35132021

ABSTRACT

OBJECTIVES: Lung damage during mechanical ventilation involves lung volume and alveolar water content, and lung ultrasound (LUS) and electrical impedance tomography changes are related to these variables. We investigated whether these techniques may detect any signal modification during the development of ventilator-induced lung injury (VILI). DESIGN: Experimental animal study. SETTING: Experimental Department of a University Hospital. SUBJECTS: Forty-two female pigs (24.2 ± 2.0 kg). INTERVENTIONS: The animals were randomized into three groups (n = 14): high tidal volume (TV) (mean TV, 803.0 ± 121.7 mL), high respiratory rate (RR) (mean RR, 40.3 ± 1.1 beats/min), and high positive-end-expiratory pressure (PEEP) (mean PEEP, 24.0 ± 1.1 cm H2O). The study lasted 48 hours. At baseline and at 30 minutes, and subsequently every 6 hours, we recorded extravascular lung water, end-expiratory lung volume, lung strain, respiratory mechanics, hemodynamics, and gas exchange. At the same time-point, end-expiratory impedance was recorded relatively to the baseline. LUS was assessed every 12 hours in 12 fields, each scoring from 0 (presence of A-lines) to 3 (consolidation). MEASUREMENTS AND MAIN RESULTS: In a multiple regression model, the ratio between extravascular lung water and end-expiratory lung volume was significantly associated with the LUS total score (p < 0.002; adjusted R2, 0.21). The variables independently associated with the end-expiratory difference in lung impedance were lung strain (p < 0.001; adjusted R2, 0.18) and extravascular lung water (p < 0.001; adjusted R2, 0.11). CONCLUSIONS: Data suggest as follows. First, what determines the LUS score is the ratio between water and gas and not water alone. Therefore, caution is needed when an improvement of LUS score follows a variation of the lung gas content, as after a PEEP increase. Second, what determines the end-expiratory difference in lung impedance is the strain level that may disrupt the intercellular junction, therefore altering lung impedance. In addition, the increase in extravascular lung water during VILI development contributed to the observed decrease in impedance.


Subject(s)
Lung Injury , Ventilator-Induced Lung Injury , Animals , Electric Impedance , Female , Humans , Lung/diagnostic imaging , Lung Injury/diagnostic imaging , Lung Injury/etiology , Positive-Pressure Respiration/methods , Swine , Tidal Volume , Tomography, X-Ray Computed , Ventilator-Induced Lung Injury/diagnostic imaging
8.
Intensive Care Med ; 48(1): 56-66, 2022 01.
Article in English | MEDLINE | ID: mdl-34825929

ABSTRACT

PURPOSE: This study aimed at investigating the mechanisms underlying the oxygenation response to proning and recruitment maneuvers in coronavirus disease 2019 (COVID-19) pneumonia. METHODS: Twenty-five patients with COVID-19 pneumonia, at variable times since admission (from 1 to 3 weeks), underwent computed tomography (CT) lung scans, gas-exchange and lung-mechanics measurement in supine and prone positions at 5 cmH2O and during recruiting maneuver (supine, 35 cmH2O). Within the non-aerated tissue, we differentiated the atelectatic and consolidated tissue (recruitable and non-recruitable at 35 cmH2O of airway pressure). Positive/negative response to proning/recruitment was defined as increase/decrease of PaO2/FiO2. Apparent perfusion ratio was computed as venous admixture/non aerated tissue fraction. RESULTS: The average values of venous admixture and PaO2/FiO2 ratio were similar in supine-5 and prone-5. However, the PaO2/FiO2 changes (increasing in 65% of the patients and decreasing in 35%, from supine to prone) correlated with the balance between resolution of dorsal atelectasis and formation of ventral atelectasis (p = 0.002). Dorsal consolidated tissue determined this balance, being inversely related with dorsal recruitment (p = 0.012). From supine-5 to supine-35, the apparent perfusion ratio increased from 1.38 ± 0.71 to 2.15 ± 1.15 (p = 0.004) while PaO2/FiO2 ratio increased in 52% and decreased in 48% of patients. Non-responders had consolidated tissue fraction of 0.27 ± 0.1 vs. 0.18 ± 0.1 in the responding cohort (p = 0.04). Consolidated tissue, PaCO2 and respiratory system elastance were higher in patients assessed late (all p < 0.05), suggesting, all together, "fibrotic-like" changes of the lung over time. CONCLUSION: The amount of consolidated tissue was higher in patients assessed during the third week and determined the oxygenation responses following pronation and recruitment maneuvers.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Humans , Lung/diagnostic imaging , Prone Position , Prospective Studies , Pulmonary Gas Exchange , SARS-CoV-2
9.
Front Physiol ; 12: 676118, 2021.
Article in English | MEDLINE | ID: mdl-34594233

ABSTRACT

Knowledge of gas volume, tissue mass and recruitability measured by the quantitative CT scan analysis (CT-qa) is important when setting the mechanical ventilation in acute respiratory distress syndrome (ARDS). Yet, the manual segmentation of the lung requires a considerable workload. Our goal was to provide an automatic, clinically applicable and reliable lung segmentation procedure. Therefore, a convolutional neural network (CNN) was used to train an artificial intelligence (AI) algorithm on 15 healthy subjects (1,302 slices), 100 ARDS patients (12,279 slices), and 20 COVID-19 (1,817 slices). Eighty percent of this populations was used for training, 20% for testing. The AI and manual segmentation at slice level were compared by intersection over union (IoU). The CT-qa variables were compared by regression and Bland Altman analysis. The AI-segmentation of a single patient required 5-10 s vs. 1-2 h of the manual. At slice level, the algorithm showed on the test set an IOU across all CT slices of 91.3 ± 10.0, 85.2 ± 13.9, and 84.7 ± 14.0%, and across all lung volumes of 96.3 ± 0.6, 88.9 ± 3.1, and 86.3 ± 6.5% for normal lungs, ARDS and COVID-19, respectively, with a U-shape in the performance: better in the lung middle region, worse at the apex and base. At patient level, on the test set, the total lung volume measured by AI and manual segmentation had a R 2 of 0.99 and a bias -9.8 ml [CI: +56.0/-75.7 ml]. The recruitability measured with manual and AI-segmentation, as change in non-aerated tissue fraction had a bias of +0.3% [CI: +6.2/-5.5%] and -0.5% [CI: +2.3/-3.3%] expressed as change in well-aerated tissue fraction. The AI-powered lung segmentation provided fast and clinically reliable results. It is able to segment the lungs of seriously ill ARDS patients fully automatically.

10.
Intensive Care Med Exp ; 9(1): 52, 2021 Oct 04.
Article in English | MEDLINE | ID: mdl-34608559

ABSTRACT

BACKGROUND: Intra-abdominal hypertension (IAH) is common in critically ill patients and is associated with increased morbidity and mortality. High positive end-expiratory pressures (PEEP) can reverse lung volume and oxygenation decline caused by IAH, but its impact on alveolar overdistension is less clear. We aimed to find a PEEP range that would be high enough to reduce atelectasis, while low enough to minimize alveolar overdistention in the presence of IAH and lung injury. METHODS: Five anesthetized pigs received standardized anesthesia and mechanical ventilation. Peritoneal insufflation of air was used to generate intra-abdominal pressure of 27 cmH2O. Lung injury was created by intravenous oleic acid. PEEP levels of 5, 12, 17, 22, and 27 cmH2O were applied. We performed computed tomography and measured arterial oxygen levels, respiratory mechanics, and cardiac output 5 min after each new PEEP level. The proportion of overdistended, normally aerated, poorly aerated, and non-aerated atelectatic lung tissue was calculated based on Hounsfield units. RESULTS: PEEP decreased the proportion of poorly aerated and atelectatic lung, while increasing normally aerated lung. Overdistension increased with each incremental increase in applied PEEP. "Best PEEP" (respiratory mechanics or oxygenation) was higher than the "optimal CT inflation PEEP range" (difference between lower inflection points of atelectatic and overdistended lung) in healthy and injured lungs. CONCLUSIONS: Our findings in a large animal model suggest that titrating a PEEP to respiratory mechanics or oxygenation in the presence of IAH is associated with increased alveolar overdistension.

11.
Intensive Care Med ; 47(10): 1130-1139, 2021 10.
Article in English | MEDLINE | ID: mdl-34529118

ABSTRACT

PURPOSE: We investigated if the stress applied to the lung during non-invasive respiratory support may contribute to the coronavirus disease 2019 (COVID-19) progression. METHODS: Single-center, prospective, cohort study of 140 consecutive COVID-19 pneumonia patients treated in high-dependency unit with continuous positive airway pressure (n = 131) or non-invasive ventilation (n = 9). We measured quantitative lung computed tomography, esophageal pressure swings and total lung stress. RESULTS: Patients were divided in five subgroups based on their baseline PaO2/FiO2 (day 1): non-CARDS (median PaO2/FiO2 361 mmHg, IQR [323-379]), mild (224 mmHg [211-249]), mild-moderate (173 mmHg [164-185]), moderate-severe (126 mmHg [114-138]) and severe (88 mmHg [86-99], p < 0.001). Each subgroup had similar median lung weight: 1215 g [1083-1294], 1153 [888-1321], 968 [858-1253], 1060 [869-1269], and 1127 [937-1193] (p = 0.37). They also had similar non-aerated tissue fraction: 10.4% [5.9-13.7], 9.6 [7.1-15.8], 9.4 [5.8-16.7], 8.4 [6.7-12.3] and 9.4 [5.9-13.8], respectively (p = 0.85). Treatment failure of CPAP/NIV occurred in 34 patients (24.3%). Only three variables, at day one, distinguished patients with negative outcome: PaO2/FiO2 ratio (OR 0.99 [0.98-0.99], p = 0.02), esophageal pressure swing (OR 1.13 [1.01-1.27], p = 0.032) and total stress (OR 1.17 [1.06-1.31], p = 0.004). When these three variables were evaluated together in a multivariate logistic regression analysis, only the total stress was independently associated with negative outcome (OR 1.16 [1.01-1.33], p = 0.032). CONCLUSIONS: In early COVID-19 pneumonia, hypoxemia is not linked to computed tomography (CT) pathoanatomy, differently from typical ARDS. High lung stress was independently associated with the failure of non-invasive respiratory support.


Subject(s)
COVID-19 , Cohort Studies , Humans , Lung/diagnostic imaging , Prospective Studies , SARS-CoV-2
12.
Front Physiol ; 12: 743153, 2021.
Article in English | MEDLINE | ID: mdl-34588999

ABSTRACT

Background: Ventilator-induced lung injury (VILI) via respiratory mechanics is deeply interwoven with hemodynamic, kidney and fluid/electrolyte changes. We aimed to assess the role of positive fluid balance in the framework of ventilation-induced lung injury. Methods: Post-hoc analysis of seventy-eight pigs invasively ventilated for 48 h with mechanical power ranging from 18 to 137 J/min and divided into two groups: high vs. low pleural pressure (10.0 ± 2.8 vs. 4.4 ± 1.5 cmH2O; p < 0.01). Respiratory mechanics, hemodynamics, fluid, sodium and osmotic balances, were assessed at 0, 6, 12, 24, 48 h. Sodium distribution between intracellular, extracellular and non-osmotic sodium storage compartments was estimated assuming osmotic equilibrium. Lung weight, wet-to-dry ratios of lung, kidney, liver, bowel and muscle were measured at the end of the experiment. Results: High pleural pressure group had significant higher cardiac output (2.96 ± 0.92 vs. 3.41 ± 1.68 L/min; p < 0.01), use of norepinephrine/epinephrine (1.76 ± 3.31 vs. 5.79 ± 9.69 mcg/kg; p < 0.01) and total fluid infusions (3.06 ± 2.32 vs. 4.04 ± 3.04 L; p < 0.01). This hemodynamic status was associated with significantly increased sodium and fluid retention (at 48 h, respectively, 601.3 ± 334.7 vs. 1073.2 ± 525.9 mmol, p < 0.01; and 2.99 ± 2.54 vs. 6.66 ± 3.87 L, p < 0.01). Ten percent of the infused sodium was stored in an osmotically inactive compartment. Increasing fluid and sodium retention was positively associated with lung-weight (R 2 = 0.43, p < 0.01; R 2 = 0.48, p < 0.01) and with wet-to-dry ratio of the lungs (R 2 = 0.14, p < 0.01; R 2 = 0.18, p < 0.01) and kidneys (R 2 = 0.11, p = 0.02; R 2 = 0.12, p = 0.01). Conclusion: Increased mechanical power and pleural pressures dictated an increase in hemodynamic support resulting in proportionally increased sodium and fluid retention and pulmonary edema.

13.
Lab Anim ; 55(5): 443-452, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33645310

ABSTRACT

Alpha2 receptor agonists (alpha2-agonists) are useful sedative and analgesic agents in sheep, but have adverse pulmonary effects, which are reportedly similar between different alpha2-agonists. This randomized crossover study compared pulmonary function after intravenous administration of an alpha2-agonist, either xylazine or an equipotent dose of medetomidine in 34 female sheep anaesthetized twice. Pulmonary function was assessed using spirometry, volumetric capnography, arterial blood gas analysis 1 min prior to, and 5 and 10 min after administration of the allocated alpha 2 agonist drug. Pulmonary structural changes were subsequently assessed using computed tomography (CT). Tachypnoea or hypoxaemia prompted reversal with atipamezole and exclusion of data. Data were analysed for a fixed effect of drug using a mixed effect linear model with significance set at p < 0.05. Ten sheep administered xylazine required atipamezole while none of sheep receiving medetomidine did. Xylazine produced significantly higher respiratory frequency, airway pressures, airway resistance and arterial carbon dioxide (CO2), and lower dynamic compliance, tidal volume, CO2 elimination and end tidal CO2 tension and arterial oxygen tension than medetomidine. This was associated with a significantly lower % of aerated tissue and higher % poorly and non-aerated tissue in CT images of sheep receiving xylazine versus medetomidine. In conclusion, xylazine administration produced marked decreases in pulmonary function, in ventilated isoflurane anaesthetized sheep, when compared to an equipotent dose of medetomidine when administered as an intravenous bolus supporting the use of medetomidine when alpha2-agonists are required.


Subject(s)
Isoflurane , Medetomidine , Animals , Female , Cross-Over Studies , Heart Rate , Hypnotics and Sedatives , Injections, Intravenous , Isoflurane/pharmacology , Medetomidine/pharmacology , Sheep , Sheep, Domestic , Xylazine/pharmacology
14.
J Appl Physiol (1985) ; 130(3): 865-876, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33439790

ABSTRACT

COVID-19 infection may lead to acute respiratory distress syndrome (CARDS) where severe gas exchange derangements may be associated, at least in the early stages, only with minor pulmonary infiltrates. This may suggest that the shunt associated to the gasless lung parenchyma is not sufficient to explain CARDS hypoxemia. We designed an algorithm (VentriQlar), based on the same conceptual grounds described by J.B. West in 1969. We set 498 ventilation-perfusion (VA/Q) compartments and, after calculating their blood composition (PO2, PCO2, and pH), we randomly chose 106 combinations of five parameters controlling a bimodal distribution of blood flow. The solutions were accepted if the predicted PaO2 and PaCO2 were within 10% of the patient's values. We assumed that the shunt fraction equaled the fraction of non-aerated lung tissue at the CT quantitative analysis. Five critically-ill patients later deceased were studied. The PaO2/FiO2 was 91.1 ± 18.6 mmHg and PaCO2 69.0 ± 16.1 mmHg. Cardiac output was 9.58 ± 0.99 L/min. The fraction of non-aerated tissue was 0.33 ± 0.06. The model showed that a large fraction of the blood flow was likely distributed in regions with very low VA/Q (Qmean = 0.06 ± 0.02) and a smaller fraction in regions with moderately high VA/Q. Overall LogSD, Q was 1.66 ± 0.14, suggestive of high VA/Q inequality. Our data suggest that shunt alone cannot completely account for the observed hypoxemia and a significant VA/Q inequality must be present in COVID-19. The high cardiac output and the extensive microthrombosis later found in the autopsy further support the hypothesis of a pathological perfusion of non/poorly ventilated lung tissue.NEW & NOTEWORTHY Hypothesizing that the non-aerated lung fraction as evaluated by the quantitative analysis of the lung computed tomography (CT) equals shunt (VA/Q = 0), we used a computational approach to estimate the magnitude of the ventilation-perfusion inequality in severe COVID-19. The results show that a severe hyperperfusion of poorly ventilated lung region is likely the cause of the observed hypoxemia. The extensive microthrombosis or abnormal vasodilation of the pulmonary circulation may represent the pathophysiological mechanism of such VA/Q distribution.


Subject(s)
COVID-19/physiopathology , Ventilation-Perfusion Ratio/physiology , Adult , Aged , COVID-19/metabolism , Cardiac Output/physiology , Female , Hemodynamics/physiology , Humans , Lung/metabolism , Lung/physiopathology , Male , Middle Aged , Oxygen/metabolism , Perfusion/methods , Pulmonary Circulation/physiology , Pulmonary Gas Exchange/physiology , Respiration , Retrospective Studies , SARS-CoV-2/pathogenicity
15.
Am J Respir Crit Care Med ; 203(3): 318-327, 2021 02 01.
Article in English | MEDLINE | ID: mdl-32813989

ABSTRACT

Rationale: Understanding the physiology of CO2 stores mobilization is a prerequisite for intermittent extracorporeal CO2 removal (ECCO2R) in patients with chronic hypercapnia.Objectives: To describe the dynamics of CO2 stores.Methods: Fifteen pigs (61.7 ± 4.3 kg) were randomized to 48 hours of hyperventilation (group "Hyper," n = 4); 48 hours of hypoventilation (group "Hypo," n = 4); 24 hours of hypoventilation plus 24 hours of normoventilation (group "Hypo-Baseline," n = 4); or 24 hours of hypoventilation plus 24 hours of hypoventilation plus ECCO2R (group "Hypo-ECCO2R," n = 3). Forty-eight hours after randomization, the current [Formula: see text]e was reduced by 50% in every pig.Measurements and Main Results: We evaluated [Formula: see text]co2, [Formula: see text]o2, and metabolic [Formula: see text]co2 ([Formula: see text]o2 times the metabolic respiratory quotient). Changes in the CO2 stores were calculated as [Formula: see text]co2 - metabolic V̇co2. After 48 hours, the CO2 stores decreased by 0.77 ± 0.17 l kg-1 in group Hyper and increased by 0.32 ± 0.27 l kg-1 in group Hypo (P = 0.030). In group Hypo-Baseline, they increased by 0.08 ± 0.19 l kg-1, whereas in group Hypo-ECCO2R, they decreased by 0.32 ± 0.24 l kg-1 (P = 0.197). In the second 24-hour period, in groups Hypo-Baseline and Hypo-ECCO2R, the CO2 stores decreased by 0.15 ± 0.09 l kg-1 and 0.51 ± 0.06 l kg-1, respectively (P = 0.002). At the end of the experiment, the 50% reduction of [Formula: see text]e caused a PaCO2 rise of 9.3 ± 1.1, 32.0 ± 5.0, 16.9 ± 1.2, and 11.7 ± 2.0 mm Hg h-1 in groups Hyper, Hypo, Hypo-Baseline, and Hypo-ECCO2R, respectively (P < 0.001). The PaCO2 rise was inversely related to the previous CO2 stores mobilization (P < 0.001).Conclusions: CO2 from body stores can be mobilized over 48 hours without reaching a steady state. This provides a physiological rationale for intermittent ECCO2R in patients with chronic hypercapnia.


Subject(s)
Acid-Base Equilibrium/physiology , Carbon Dioxide/metabolism , Chronic Disease/therapy , Hypercapnia/therapy , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/therapy , Pulmonary Gas Exchange/physiology , Animals , Extracorporeal Membrane Oxygenation , Humans , Models, Animal , Swine
16.
Intensive Care Med ; 46(12): 2187-2196, 2020 12.
Article in English | MEDLINE | ID: mdl-33089348

ABSTRACT

PURPOSE: To investigate whether COVID-19-ARDS differs from all-cause ARDS. METHODS: Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO2/FiO2 or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH2O PEEP. CT scan variables were measured at 5 cmH2O PEEP. RESULTS: Anthropometric characteristics were similar in COVID-19-ARDS, PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS. The PaO2/FiO2-matched-ARDS and COVID-19-ARDS populations (both with PaO2/FiO2 106 ± 59 mmHg) had different respiratory system compliances (Crs) (39 ± 11 vs 49.9 ± 15.4 ml/cmH2O, p = 0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1 ± 15.7 and 49.9 ± 15.4 ml/cmH2O, respectively) but significantly lower PaO2/FiO2 for the same Crs (160 ± 62 vs 106.5 ± 59.6 mmHg, p < 0.001). The three populations had similar lung weights but COVID-19-ARDS had significantly higher lung gas volume (PaO2/FiO2-matched-ARDS 930 ± 644 ml, COVID-19-ARDS 1670 ± 791 ml and Compliance-matched-ARDS 1301 ± 627 ml, p < 0.05). The venous admixture was significantly related to the non-aerated tissue in PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS (p < 0.001) but unrelated in COVID-19-ARDS (p = 0.75), suggesting that hypoxemia was not only due to the extent of non-aerated tissue. Increasing PEEP from 5 to 15 cmH2O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO2/FiO2-matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution. CONCLUSIONS: COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO2/FiO2, at least when considered within the timeframe of our study.


Subject(s)
COVID-19/physiopathology , Respiratory Distress Syndrome/physiopathology , Adult , Aged , Blood Gas Analysis/methods , COVID-19/therapy , Cohort Studies , Female , Humans , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Italy , Length of Stay/statistics & numerical data , Lung Compliance/physiology , Male , Middle Aged , Prospective Studies , Pulmonary Gas Exchange/physiology , Respiratory Distress Syndrome/therapy , Simplified Acute Physiology Score , Tomography, X-Ray Computed/methods
17.
Anesthesiology ; 132(5): 1126-1137, 2020 05.
Article in English | MEDLINE | ID: mdl-32032095

ABSTRACT

BACKGROUND: Excessive tidal volume, respiratory rate, and positive end-expiratory pressure (PEEP) are all potential causes of ventilator-induced lung injury, and all contribute to a single variable: the mechanical power. The authors aimed to determine whether high tidal volume or high respiratory rate or high PEEP at iso-mechanical power produce similar or different ventilator-induced lung injury. METHODS: Three ventilatory strategies-high tidal volume (twice baseline functional residual capacity), high respiratory rate (40 bpm), and high PEEP (25 cm H2O)-were each applied at two levels of mechanical power (15 and 30 J/min) for 48 h in six groups of seven healthy female piglets (weight: 24.2 ± 2.0 kg, mean ± SD). RESULTS: At iso-mechanical power, the high tidal volume groups immediately and sharply increased plateau, driving pressure, stress, and strain, which all further deteriorated with time. In high respiratory rate groups, they changed minimally at the beginning, but steadily increased during the 48 h. In contrast, after a sudden huge increase, they decreased with time in the high PEEP groups. End-experiment specific lung elastance was 6.5 ± 1.7 cm H2O in high tidal volume groups, 10.1 ± 3.9 cm H2O in high respiratory rate groups, and 4.5 ± 0.9 cm H2O in high PEEP groups. Functional residual capacity decreased and extravascular lung water increased similarly in these three categories. Lung weight, wet-to-dry ratio, and histologic scores were similar, regardless of ventilatory strategies and power levels. However, the alveolar edema score was higher in the low power groups. High PEEP had the greatest impact on hemodynamics, leading to increased need for fluids. Adverse events (early mortality and pneumothorax) also occurred more frequently in the high PEEP groups. CONCLUSIONS: Different ventilatory strategies, delivered at iso-power, led to similar anatomical lung injury. The different systemic consequences of high PEEP underline that ventilator-induced lung injury must be evaluated in the context of the whole body.


Subject(s)
Models, Animal , Positive-Pressure Respiration/adverse effects , Respiratory Mechanics/physiology , Tidal Volume/physiology , Ventilator-Induced Lung Injury/physiopathology , Animals , Animals, Newborn , Female , Positive-Pressure Respiration/methods , Swine , Ventilator-Induced Lung Injury/etiology
18.
Anesthesiology ; 130(1): 119-130, 2019 01.
Article in English | MEDLINE | ID: mdl-30277932

ABSTRACT

BACKGROUND: Positive end-expiratory pressure is usually considered protective against ventilation-induced lung injury by reducing atelectrauma and improving lung homogeneity. However, positive end-expiratory pressure, together with tidal volume, gas flow, and respiratory rate, contributes to the mechanical power required to ventilate the lung. This study aimed at investigating the effects of increasing mechanical power by selectively modifying its positive end-expiratory pressure component. METHODS: Thirty-six healthy piglets (23.3 ± 2.3 kg) were ventilated prone for 50 h at 30 breaths/min and with a tidal volume equal to functional residual capacity. Positive end-expiratory pressure levels (0, 4, 7, 11, 14, and 18 cm H2O) were applied to six groups of six animals. Respiratory, gas exchange, and hemodynamic variables were recorded every 6 h. Lung weight and wet-to-dry ratio were measured, and histologic samples were collected. RESULTS: Lung mechanical power was similar at 0 (8.8 ± 3.8 J/min), 4 (8.9 ± 4.4 J/min), and 7 (9.6 ± 4.3 J/min) cm H2O positive end-expiratory pressure, and it linearly increased thereafter from 15.5 ± 3.6 J/min (positive end-expiratory pressure, 11 cm H2O) to 18.7 ± 6 J/min (positive end-expiratory pressure, 14 cm H2O) and 22 ± 6.1 J/min (positive end-expiratory pressure, 18 cm H2O). Lung elastances, vascular congestion, atelectasis, inflammation, and septal rupture decreased from zero end-expiratory pressure to 4 to 7 cm H2O (P < 0.0001) and increased progressively at higher positive end-expiratory pressure. At these higher positive end-expiratory pressure levels, striking hemodynamic impairment and death manifested (mortality 0% at positive end-expiratory pressure 0 to 11 cm H2O, 33% at 14 cm H2O, and 50% at 18 cm H2O positive end-expiratory pressure). From zero end-expiratory pressure to 18 cm H2O, mean pulmonary arterial pressure (from 19.7 ± 5.3 to 32.2 ± 9.2 mmHg), fluid administration (from 537 ± 403 to 2043 ± 930 ml), and noradrenaline infusion (0.04 ± 0.09 to 0.34 ± 0.31 µg · kg(-1) · min(-1)) progressively increased (P < 0.0001). Lung weight and lung wet-to-dry ratios were not significantly different across the groups. The lung mechanical power level that best discriminated between more versus less severe damage was 13 ± 1 J/min. CONCLUSIONS: Less than 7 cm H2O positive end-expiratory pressure reduced atelectrauma encountered at zero end-expiratory pressure. Above a defined power threshold, sustained positive end-expiratory pressure contributed to potentially lethal lung damage and hemodynamic impairment.


Subject(s)
Lung/physiopathology , Positive-Pressure Respiration/adverse effects , Positive-Pressure Respiration/methods , Ventilator-Induced Lung Injury/prevention & control , Animals , Disease Models, Animal , Swine
19.
Crit Care ; 22(1): 121, 2018 May 09.
Article in English | MEDLINE | ID: mdl-29743121

ABSTRACT

BACKGROUND: Recent clinical studies have not shown an overall benefit of high-frequency oscillatory ventilation (HFOV), possibly due to injurious or non-individualized HFOV settings. We compared conventional HFOV (HFOVcon) settings with HFOV settings based on mean transpulmonary pressures (PLmean) in an animal model of experimental acute respiratory distress syndrome (ARDS). METHODS: ARDS was induced in eight pigs by intrabronchial installation of hydrochloric acid (0.1 N, pH 1.1; 2.5 ml/kg body weight). The animals were initially ventilated in volume-controlled mode with low tidal volumes (6 ml kg- 1) at three positive end-expiratory pressure (PEEP) levels (5, 10, 20 cmH2O) followed by HFOVcon and then HFOV PLmean each at PEEP 10 and 20. The continuous distending pressure (CDP) during HFOVcon was set at mean airway pressure plus 5 cmH2O. For HFOV PLmean it was set at mean PL plus 5 cmH2O. Baseline measurements were obtained before and after induction of ARDS under volume controlled ventilation with PEEP 5. The same measurements and computer tomography of the thorax were then performed under all ventilatory regimens at PEEP 10 and 20. RESULTS: Cardiac output, stroke volume, mean arterial pressure and intrathoracic blood volume index were significantly higher during HFOV PLmean than during HFOVcon at PEEP 20. Lung density, total lung volume, and normally and poorly aerated lung areas were significantly greater during HFOVcon, while there was less over-aerated lung tissue in HFOV PLmean. The groups did not differ in oxygenation or extravascular lung water index. CONCLUSION: HFOV PLmean is associated with less hemodynamic compromise and less pulmonary overdistension than HFOVcon. Despite the increase in non-ventilated lung areas, oxygenation improved with both regimens. An individualized approach with HFOV settings based on transpulmonary pressure could be a useful ventilatory strategy in patients with ARDS. Providing alveolar stabilization with HFOV while avoiding harmful distending pressures and pulmonary overdistension might be a key in the context of ventilator-induced lung injury.


Subject(s)
High-Frequency Ventilation/standards , Monitoring, Physiologic/methods , Pressure , Respiratory Distress Syndrome/therapy , Animals , Arterial Pressure/physiology , Blood Volume Determination/methods , Cardiac Output/physiology , High-Frequency Ventilation/methods , Lung/blood supply , Lung/metabolism , Lung/physiopathology , Monitoring, Physiologic/statistics & numerical data , Monitoring, Physiologic/trends , Positive-Pressure Respiration/methods , Pulmonary Gas Exchange/physiology , Stroke Volume/physiology , Swine
20.
Am J Respir Crit Care Med ; 197(12): 1586-1595, 2018 06 15.
Article in English | MEDLINE | ID: mdl-29345967

ABSTRACT

RATIONALE: The ratio of PaO2 to FiO2 (P/F) defines acute respiratory distress syndrome (ARDS) severity and suggests appropriate therapies. OBJECTIVES: We investigated 1) whether a 150-mm-Hg P/F threshold within the range of moderate ARDS (100-200 mm Hg) would define two subgroups that were more homogeneous; and 2) which criteria led the clinicians to apply extracorporeal membrane oxygenation (ECMO) in severe ARDS. METHODS: At the 150-mm-Hg P/F threshold, moderate patients were split into mild-moderate (n = 50) and moderate-severe (n = 55) groups. Patients with severe ARDS (FiO2 not available in three patients) were split into higher (n = 63) and lower (n = 18) FiO2 groups at an 80% FiO2 threshold. MEASUREMENTS AND MAIN RESULTS: Compared with mild-moderate ARDS, patients with moderate-severe ARDS had higher peak pressures, PaCO2, and pH. They also had heavier lungs, greater inhomogeneity, more noninflated tissue, and greater lung recruitability. Within 84 patients with severe ARDS (P/F < 100 mm Hg), 75% belonged to the higher FiO2 subgroup. They differed from the patients with severe ARDS with lower FiO2 only in PaCO2 and lung weight. Forty-one of 46 patients treated with ECMO belonged to the higher FiO2 group. Within this group, the patients receiving ECMO had higher PaCO2 than the 22 non-ECMO patients. The inhomogeneity ratio, total lung weight, and noninflated tissue were also significantly higher. CONCLUSIONS: Using the 150-mm-Hg P/F threshold gave a more homogeneous distribution of patients with ARDS across the severity subgroups and identified two populations that differed in their anatomical and physiological characteristics. The patients treated with ECMO belonged to the severe ARDS group, and almost 90% of them belonged to the higher FiO2 subgroup.


Subject(s)
Dyspnea/therapy , Extracorporeal Membrane Oxygenation/methods , Respiration, Artificial/methods , Respiratory Distress Syndrome/classification , Respiratory Distress Syndrome/therapy , Adult , Aged , Aged, 80 and over , Chile , Dyspnea/diagnosis , Female , Germany , Humans , Italy , Male , Middle Aged , Respiratory Distress Syndrome/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...